Home > PAINT & SUNDRIES > SUNDRIES > CAULKING > FIRE & SMOKE SEALANTS
Sort By:
1
Dap 18854 Fireplace And Stove Sealants White Lightning 8803030 Flamebuster Heat Fire Block Sealant 3M FB 136 Fire Block Sealant
Patches and seals around fireplaces and wood-burning stoves. Withstands temperatures up to 2000 degrees Fahrenheit. Sets rock hard when fired. Water clean up. Noncombustible caulk designed to resist high-temperatures and smoke in non-rated construction. Blocks drafts, smoke and fire. Use around wires, pipes, ducts and vents. Resists temperatures up to 1,380 degrees Fahrenheit. Meets ASTM specifications E-136. Designed to resist high temperatures and smoke passage in non-rated construction. Can be used with a standard caulking gun, or pneumatic pumping equipment. Easily applied with a putty knife or trowel. Fast-dry, tack-free in 15 minutes. Gray in color. Meets ASTM E - 136, 2003 IRC, 2003 IBC.
Rectorseal 66648 Firestopping Sealant 3M IC15 WB+ Fire Barrier Sealant FOAM FIRE BLOCK ORANGE 21.1OZ
One component, general purpose fire rated sealant and smoke seal for construction joints and through-penetrations. No-sag caulking grade sealant. Cures to an elastomeric seal that is suitable where dynamic movement is expected. 10.3 ounce covers 18 cu. in. Designed for use as a one-part fire, smoke, noxious gas and water resistant sealant. Easy cleanup no special handling, routine disposal. Intumescent,  Fast dry, tack-free, in 8-12 minutes. Paintable after 72 hour cure. Meets ASTM E 814 and ASTM E 1966. Designed specifically for use Type VA, occupancy group R3 and R5 (wood frame) buildings, to seal openings in concealed spaces to resist the migration of fire and hot gases. The Fire Block foam cures upon reaction with moisture to form a flexible, urethane foam that is effective against the passage of smoke and toxic gases through service penetrations. Foam adheres to most types of building materials including wood, concrete, brick, metals, cable jacketing; and will not harm PVC, CPVC and PEX pipe/tubing. It complies with all Federal and State VOC regulations.
3M CP25WB Fire Barrier Caulk Rectorseal 66640 Metacaulk 1000 Firestopping Sealant White Lightning 8802020 Flamebuster Heat Fire Block Sealant
Forms a tight barrier against fire, smoke and toxic fumes. Suitable for a wide variety of through-penetration fire stops, including cable, metal pipe, insulated pipe, glass pipe, construction gaps, HVAC ductwork and certain plastic pipe applications. Cures to form a flexible seal, installs with a standard caulking gun, pneumatic pumping equipment or putty knife. ASTM, FM and U.L. tested for 3 hour fire penetration seal for walls and floors. One component, general purpose fire rated sealant and smoke seal for construction joints and through-penetrations. Extremely intumescent, non-sag caulking grade sealant. Cures to an elastomeric seal that is suitable where dynamic movement is expected. 10.3 ounce covers about 18 cu. in. Designed for wall and floor applications in UL rated construction. Use on aluminum, pre-cast concrete gypsum, wall board, power/communication cables and aluminum/galvanized steel cable trays, static/non-static pipes and conduits, CPVC, PVC, and steel. Resists cracking. Forms pressure tight seal resistant to water, smoke and toxic gases. Withstands temperatures up to 300 degrees Fahrenheit. Can be applied at temperatures from negative 20 degrees Fahrenheit to 122 degrees Fahrenheit. Meets ASTM E-814 (UL1479) and FBC System Compatible. ASTM specifications C-920, Type S, Grade NS, Class 25.
3M FIREDAM 150+ BLUE Fire Barrier Sealant Dap 18858 Blockade Fire/Smoke Sealant Dap 18806 Fire Stop Fire Barrier Sealant
Used to firestop metal pipes or cables through concrete or gypsum, and head of wall systems. Dries to touch in 30 - 60 minutes. Meets ASTM E 814,  ASTM E 1966. Used for all combustible and non-combustible penetrations, excellent adhesion to unprimed surfaces. Classified for sealing fire-rated non-combustible service penetrations and construction joints in horizontal and vertical fire separations. Single component silicone fire barrier for sealing around piping and wiring penetrations through fire-rated walls and floors. U.L. Listed; meets ASTM Specifications E-814, UL1479 and UL2079. Service Temperature Range: -51C to 149C (-51F to 300F). Application Temperature Range: -29 C to 50C (-20F to 122F).
3M 1000NS Water Tight Fire Barrier Sealant Henkel 1390035 Greenseries - Flameseal Fire/Smoke/Draft Stop Sealant 3M ULTRAPPD3.0 Fire Barrier Pipe Collar
NS Series- No slumping of vertical joints, gravity will hold positioning. Ready to use with a standard or bulk caulking gun or pneumatic pumping equipment. Cures in 20-40 minutes. Used to firestop openings and penetrations on fire rated floor stabs, walls, other building partitions and assemblies. Helps control the spread of fire, smoke and noxious gases. Meets ASTM Specification C920, Type S, Grade P, Class 25. Used to seal service penetrations and joints in fire separations and firewalls. Stops flame, smoke, and fumes under actual fire conditions. Easy to apply and cleanup, contains NO asbestos, paintable after cure. Nonflammable, provides a fireproof acoustic seal. GREENGUARD approved, meets LEED requirements. One-piece metal collar assembly encasing heat expanding 3m Fire Barrier Wrap Strip Ultra GS material. Used to firestop non-metallic pipe, cables and combos in new and retrofit installations. Achieves up to 3-hour fire protection in tested and listed systems.
3M ULTRAPPD4.0 Fire Barrier Pipe Collar 3M CP-25WB Fire Barrier Sealant
One-piece metal collar assembly encasing heat expanding 3m Fire Barrier Wrap Strip Ultra GS material. Used to firestop non-metallic pipe, cables and combos in new and retrofit installations. Achieves up to 3-hour fire protection in tested and listed systems. Provides up to 4-hour protection in tested and listed systems. Penetrates through fire-rated construction assemblies. Dries to red color, no mixing required. Helps prevent the spread of fire, smoke and noxious gas. Acts as an acoustic barrier by minimizing noise transfer. Helps create a smoke seal for systems requiring the optional L-Rating. Meets the intent of LEED VOC environmental regulations, international building code and other key life safety building code requirements.
   
 
1