Home > HARDWARE > CONSTRUCTION HARDWARE > JOIST HANGERS & CONNECTORS > FRAMING ANGLES/ANCHORS
Sort By:
1
USP Lumber MP34 Framing Angle USP Lumber RT7A Double Plate Hurricane/Seismic Anchor USP Lumber RT7 Double Plate Hurricane/Seismic Anchor
Use for joist/header installations. Does not have tabs. G90 galvanizing finish. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505; ICBO 5736; DSA PA-076; Dade County, FL 01-0417.11; and  L.A. City RR25303 codes. 18 Gauge. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber RT3A Double Plate Hurricane/Seismic Anchor USP Lumber RT Hurricane/Seismic Anchor USP Lumber RT5 Double Plate Hurricane/Seismic Anchor
Ties trusses and rafters to top plates either left or right handed. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. G90 galvanizing finish. Requires 8d nails for installation in plate and rafter/truss. Meets ICC-ES ESR-1465 and FL817 codes. 18 Gauge. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber MPA1 Framing Angle USP Lumber RT15 Double Plate Hurricane/Seismic Anchor USP Lumber JA1-TZ Framing Angle
Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc finish requires 8d HDGnails for installation in plate and rafter/truss and Gold Coat anchor requires N8-GC nails. 1-9/16"W x 2-5/8"H opening. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Contractors charts in the Orgill paper catalog R7 for reference pages. 18 GAUGE - 5-1/4"H. Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505; L.A. City RR25303, DSA PA-076; and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 16 Gauge.
USP Lumber RT Hurricane/Seismic Anchor USP Lumber MPA1 Framing Angle ANGLE 2X-2X TRIPLE ZINC 16GA
Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc finish requires 8d HDGnails for installation in plate and rafter/truss and Gold Coat anchor requires N8-GC nails. 1-9/16"W x 2-5/8"H opening. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Contractors charts in the Orgill paper catalog R7 for reference pages. 18 GAUGE - 5-1/4"H. Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. An angle connects two 2x wood members at 90? angles; G185 galvanizing finish; requires (8) USP LumberLok LL915 (#9 x 1-3/8" long) wood screws not included.
ANGLE 2X4IN TRIPLE ZINC 12GA  USP Lumber A3 Framing Angle USP Lumber MP5-TZ Framing Angle
Provides a 90? connection for medium/heavy duty applications; stronger than angled nailing or screw fastening; help ensure joints are consistently straight and strong. Eliminates toenailing and increases strength. Requires 10d x 1-1/2" nails for installation. 1-7/16"W1 X 1-7/16"W2 X 2-3/4"L - 18 GAUGE. Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. May be field adjusted by hand from 0 to 135 degrees, giving framers and do-it-yourselfers flexibility in applications. Bend angle only once. G90 galvanized finish. 10d HDG nails required for installation. Meets SBCCI, BOCA - NER 530, ICBO 5700, FL822, L.A. City RR 25337, DSA PA-06 codes.
USP Lumber AC5-TZ Framing Angle ANGLE 2X6IN TRIPLE ZINC 12GA  USP Lumber AC7 Framing Angle
For general-purpose reinforcements of many framing connections. G185 galvanized finish. Can be used in both new construction and retrofit applications. Staggered nail patterns reduce wood splitting and allows installation on both sides of the supported member. Triple Zinc clips require 10d HDG or 16d HDG nails.  Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. For additional information including allowable loads and number of fasteners, please see USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Provides a 90? connection for medium/heavy duty applications; stronger than angled nailing or screw fastening; help ensure joints are consistently straight and strong. For general-purpose reinforcements of many framing connections. G185 galvanized finish. Can be used in both new construction and retrofit applications. Staggered nail patterns reduce wood splitting and allows installation on both sides of the supported member. Triple Zinc clips require 10d HDG or 16d HDG nails.  Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. For additional information including allowable loads and number of fasteners, please see USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber SCA Stair Angle USP Lumber SCA Stair Angle USP Lumber WE44-TZ Wet Post Anchor
Simplifies stair construction and eliminate the need to calculate and notch stair stringers. Stronger and safer than wood blocking, and the angle and fasteners are hidden from view. Use the SCA9 for single 2x10 stair treads and SCA10 for double 2 x 6 stair treads. Requires 1/4" x 1-1/2" lag bolts. Meets ICC-ES ESR-1280, FL11664 and L.A. City RR25749 codes. For additional information on installation, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Simplifies stair construction and eliminate the need to calculate and notch stair stringers. Stronger and safer than wood blocking, and the angle and fasteners are hidden from view. Use the SCA9 for single 2x10 stair treads and SCA10 for double 2 x 6 stair treads. Requires 1/4" x 1-1/2" lag bolts. Meets ICC-ES ESR-1280, FL11664 and L.A. City RR25749 codes. For additional information on installation, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Secures posts to concrete in light-duty and medium-duty applications such as patio covers, carports or decks. Formed, one-piece design includes embossing for additional lateral strength. Not  for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires (2) 1/2" HDG bolts or (12) HDG nails for fastening to post. Meets SBCCI, BOCA - NER 530 & NER 608, ICBO 5700, ICBO 2039, ICBO 5531, FL821, FL822, L.A. City RR 25337, and DSA PA-076 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
   
 
1