USP Lumber RT7A Double Plate Hurricane/Seismic Anchor USP Lumber RT7 Double Plate Hurricane/Seismic Anchor USP Lumber KNS1 Protection Plate
Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Easy to install for protecting plumbing and power or communication wiring from screw or nail penetration. 16 gauge, 1/16" thick. Conforms to National Electric Code.
USP Lumber MP34 Framing Angle USP Lumber RT3A Double Plate Hurricane/Seismic Anchor USP Lumber NP Truss Mending Plate
Use for joist/header installations. Does not have tabs. G90 galvanizing finish. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505; ICBO 5736; DSA PA-076; Dade County, FL 01-0417.11; and  L.A. City RR25303 codes. 18 Gauge. Ties trusses and rafters to top plates either left or right handed. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. G90 galvanizing finish. Requires 8d nails for installation in plate and rafter/truss. Meets ICC-ES ESR-1465 and FL817 codes. 18 Gauge. Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge.
USP Lumber FB24-TZ Fence Bracket USP Lumber RT5 Double Plate Hurricane/Seismic Anchor USP Lumber RT Hurricane/Seismic Anchor
Provides stronger fence connections and simplifies fence assembly. Can be installed before posts are set to help ensure uniform spacing and alignment. Requires five 6d HDG fasteners for rails and three 8d HDG fasteners for posts. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber NP35 Truss Mending Plate USP Lumber TPP24 Prong Mending Plate USP Lumber RT15 Double Plate Hurricane/Seismic Anchor
Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge. Prong plates with straight prongs. Joins flat surfaces of 2 or more wood members. Not for structural use OR use in truss assembly; no load ratings assigned. G90 galvanizing finish. 22 Gauge. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc finish requires 8d HDGnails for installation in plate and rafter/truss and Gold Coat anchor requires N8-GC nails. 1-9/16"W x 2-5/8"H opening. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Contractors charts in the Orgill paper catalog R7 for reference pages. 18 GAUGE - 5-1/4"H.
USP Lumber JUS26 Double Shear Slant Joist Hanger USP Lumber JL24 Standard Joist Hanger USP Lumber PL4 Protection Plate
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Easy-to-install for protecting plumbing and power or communication wiring from screw or nail penetration. Conforms to National Electric Code. 16 Gauge - 1/16" Thickness.
USP Lumber ST12 Strap Tie USP Lumber JUS24 Double Shear Slant Joist Hanger USP Lumber JA1-TZ Framing Angle
Connects wood framing to resist tension forces. G90 galvanizing finish. ST Medium-duty series require 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. 16 Gauge. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505; L.A. City RR25303, DSA PA-076; and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 16 Gauge.
USP Lumber MPA1 Framing Angle USP Lumber JUS24-TZ Double Shear Slant Joint Hanger USP Lumber JUS26-TZ Double Shear Slant Joint Hanger
Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber JL26 Standard Joist Hanger USP Lumber NP37 Truss Mending Plate USP Lumber RT Hurricane/Seismic Anchor
G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc finish requires 8d HDGnails for installation in plate and rafter/truss and Gold Coat anchor requires N8-GC nails. 1-9/16"W x 2-5/8"H opening. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Contractors charts in the Orgill paper catalog R7 for reference pages. 18 GAUGE - 5-1/4"H.
USP Lumber TPP Truss Mending Plate Simpson Strong-Tie LSTA Light Duty Strap Tie USP Lumber LSTA12 Light Capacity Strap Tie
Prong plates with straight prongs. Joins flat surfaces of 2 or more wood members. Not for structural use OR use in truss assembly; no load ratings assigned. G90 galvanizing finish. 22 Gauge. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber JUS28 Double Shear Slant Joist Hanger USP Lumber JUS210 Double Shear Slant Joist Hanger USP Lumber MPA1 Framing Angle
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
   
 